ECO-FLAME STOP GYM

ECO-WELLNESS Logo

ECO-WELLNESS

Rubber gym flooring and accessories for gyms, fitness centers, and sports facilities.

Fire reaction class Bfl-s1

Indoor sports flooring made of recycled rubber with fire reaction class Bfl-s1

ECO-FLAME STOP GYM is a modular resilient flooring system made from recycled SBR rubber, designed for gyms and indoor fitness facilities with the most stringent fire safety requirements.

Flame Exposure Test on the Surface of ECO-FLAME STOP GYM Flooring

Reaction to Fire

Bfl-s1 · EN 13501-1

What is it?

A modular, resilient, installed sports flooring system made from recycled SBR rubber and designed for indoor use.

Where it is used

Fitness areas, free-weight areas, functional training zones, personal training studios, hallways, and indoor exercise circuits.

Overview

It is not a construction product because it is not intended to be permanently incorporated into a building.

Bfl-s1
Classification according to EN 13501-1.

Indoor use
Not suitable for prolonged exposure to UV rays and the elements.

Surface-mounted installation
Modular system that can be stabilized according to the design.


smooth surface. Seamless version.

Color: Black
Uncolored finish.

01 / Product

Modular, surface-mounted flooring for indoor sports facilities

ECO-FLAME STOP GYM is made from a blend of recycled rubber designed to improve resistance to flame spread and reduce smoke emissions in the event of combustion. Its Bfl-s1 classification allows it to be used in indoor environments with stricter safety requirements, including areas adjacent to escape routes, subject to verification of the specific project’s requirements.

Product Classification

ECO-FLAME STOP GYM is a modular, loose-lay resilient flooring system, as defined by EN ISO 2424:2012.

Since it is placed or secured solely for the purpose of stabilizing the plates and is not intended to be permanently incorporated into a building, it does not fall under the definition of a construction product within the meaning of Regulation (EU) No. 305/2011 (CPR).

Version and Mounting

The product is available with a smooth, seamless surface.

Upon request, we can provide the LOCK mechanical fastening system to stabilize the plates relative to one another without altering the walking surface.

02 / Test and Details

Fire Performance: Visual Documentation of the Surface

The images show the product’s exposure to the flame and the condition of the flooring after the test. The product’s classification is based on the tests described in the technical documentation and not solely on observation of the photographs.

03 / Applications

Where to Use ECO-FLAME STOP GYM

This flooring is designed exclusively for indoor use. It is not suitable for prolonged exposure to UV rays or outdoor weather conditions.

Indoor Fitness Areas

Flooring for indoor spaces used for training and physical activity.

Weight rooms and functional training areas

Modular solution for free-weight areas and functional training areas.

Personal Training Studios

A resilient surface for areas intended for individual training.

Hallways and interior pathways

Used in pathways and internal connecting areas.

Environments with Bfl-s1 requirements

It may also be used in areas adjacent to escape routes, provided this is specified and verified in the design.

04 / Dimensions

Available sizes

The table provides a summary of the available size configurations.

THICKNESS (mm)20304050
1000 × 1000 (mm)●●●●

05 / Fire Performance

Bfl-s1 classification according to EN 13501-1

The flooring has been classified as Bfl-s1 based on the tests required for flooring. This classification allows for its use in indoor environments with more stringent safety requirements; compatibility with a specific project must be verified by the designated technician.

Classification

Bfl-s1

Fire reaction classification of flooring in accordance with EN 13501-1.

Exposure to Fire

EN ISO 11925-2

The test with a 15-second exposure yielded the expected result.

Radiant panel

EN ISO 9239-1

This test is used to determine the classification of the pavement.

06 / Materials and Color

Material, Surface, and Color

ECO-FLAME STOP GYM is composed of recycled SBR rubber granules, derived primarily from end-of-life tyres, bound with polyurethane resin. The base layer uses a selected medium-grain size of less than 3 mm; the surface layer is made with a selected fine-grain size.

The product is available in uncolored black. Small dots, micro-irregularities, and slight color variations are inherent characteristics of recycled rubber and do not compromise the performance or overall appearance of the flooring.

07 / Installation

Installation and Layout Diagrams

The flooring is designed for modular, loose-lay installation. Upon completion of the work, the surface must be even, stable, and free of any lifting.

Substrate Preparation

Stable and level

The surface must be dry, clean, and free of dust or imperfections that could compromise the system’s stability.

Installation Diagram

In a grid pattern or staggered

The plates must be aligned precisely. A staggered arrangement is generally recommended to distribute loads more evenly and improve overall stability.

Stabilization

LOCK or additional fastening

When required by the project, installation can be supplemented with polyurethane adhesive, double-sided tape, or the LOCK mechanical system, to be determined based on the subfloor and the expected duration of use.

08 / Cleaning

Cleaning and Maintenance

Regular cleaning helps maintain hygiene and preserve the surface’s properties over time.

Routine cleaning

Vacuuming and a neutral cleaner

Remove dirt with a vacuum cleaner equipped with a HEPA filter, then wipe with a microfiber cloth and a mild, rubber-safe cleaner, avoiding excessive amounts of water.

Deep Cleaning

Wash-and-dry cycle or soft brush

For routine cleaning, you can use a scrubber-dryer or treat stains locally with a mild detergent and a soft-bristled brush.

Products to Avoid

Solvents, waxes, acids, and alkalis

Do not use solvents, acidic or alkaline cleaners, or wax-based products, as they may damage the surface.

09 / Documentation

Fire Reaction, REACH, and EN 71-3

We provide the technical documentation available for evaluating the project. Before placing your order, please specify the intended use, the characteristics of the substrate, the fire performance requirements, and any necessary documents.

EN 13501-1
Fire reaction classification: Bfl-s1.

REACH (EC) No. 1907/2006
This product is classified as an article; it does not require a Safety Data Sheet. According to the available documentation, it does not contain SVHC substances in concentrations exceeding 0.1% w/w.

EN 71-3:2019
The mixture used for the base complies with the specified limits for the migration of elements, based on tests conducted at an accredited laboratory.

CPR Classification
Modular flooring not intended to be permanently incorporated into a building structure; it does not fall under the definition of a construction product.

10 / FAQ

ECO-FLAME STOP GYM Technical FAQs

Brief answers regarding the product’s features, indoor use, and classification.

What does the Bfl-s1 classification mean?

Indicates the fire reaction class assigned to the flooring in accordance with EN 13501-1, based on the tests specified for this type of product.

Can the ECO-FLAME STOP GYM be used outdoors?

No. The product is designed for indoor use and is not intended for prolonged exposure to UV rays or the elements.

Is ECO-FLAME STOP GYM a construction product?

No. It is a modular resilient flooring system that is laid or secured solely for stabilization purposes and is not intended to be permanently incorporated into a building structure; therefore, it does not fall under the definition of a construction product pursuant to Regulation (EU) No. 305/2011.

Is a mechanical fastening system available?

Yes. Upon request, we can provide the LOCK system for interlocking the plates without altering the walking surface.

Can it be used in areas adjacent to emergency exits?

The technical documentation specifies its use in indoor environments with more stringent requirements, including areas adjacent to escape routes. The technician in charge must verify that the solution complies with the specific project.

Technical Request

Request a technical evaluation for ECO-FLAME STOP GYM

Please contact us with details regarding the intended use, the area to be paved, the characteristics of the subfloor, and any fire-resistance requirements. We will evaluate the available configuration and provide the relevant technical documentation.

Before making contact, prepare the following:

  • Approximate area in m²;
  • intended use and environmental characteristics;
  • type and condition of the substrate;
  • Fire-resistance requirements and required documentation.
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.